Visit
Official Website
Voltage DetectorsInsulation PolesEarthing and Short-Curcuit EquipmentInsulationPersonal Protection EquipmentLockout & Tagout (LOTO)First Aid and PreventionLadderDisplayARC Flash Protection Suits Arc Flash Suit Fibre Glass Ladders & Work PlatformsSignalizationUlirvision - Thermal Monitoring System Others

Saturn Pyro Sdn Bhd
44 & 44A, Jalan Palma Rafis 1,
Taman Dato Chellam,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8660510
+607-8660511

Saturn Pyro Sdn Bhd
Johor Bahru Office
44 & 44A, Jalan Palma Rafis 1,
Taman Dato Chellam,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8660510
+607-8660511
enquiry@saturnpyro.com
 
Shah Alam Office
K03-03-12, Tower 3,
UOA Business Park,
No 1, Jalan
Pengaturcara U1/51A,
Section U1, Kawasan
Perindustrian Temasya,
40150 Shah Alam,
Selangor, Malaysia.
+607-8660510
+607-8660511
Penang Office
Penthouse 1-21-1,
Suntech @ Penang Cybercity
Lintang Mayang Pasir 3,
11950 Bayan Baru,
Penang, Malaysia.
+607-8660510
+607-8660511
desmond@saturnpyro.com

Bangalore Office
Saturnpyro Solutions Pvt. Ltd.

SFS-B-38, 1st Floor, 7th B Main Road,
Yelahanka New Town, Bangalore 560 064.
GSTIN: 29ABCCS4606C1ZK
+91 829 192 0602
+601 7488 7001
 
India Office
3, Gr Floor, Eishita,
Shiv Vallabh Cross Road,
Ashokvan, Dahisar (E.),
Mumbai 400068.
+91 22284 84682
+91 98191 56654


Mod. VTA

Previous 1 / 2 Next


Electronic voltage detector by micro controller and direct contact detection. New advanced technology acquisition by pulse of light that guarantees a perfect and safe indication even in conflicting electric field environments.
Work temperature range: from -25°C to +55°C.
Self-checking system for its complete circuit by pressing test button. Self-ignition when voltage presence.
Auto turn-off into sleep mode after two minutes of voltage absence. In this mode consumption is less than 1µA.
Voltage presence is indicated by high luminosity red LED and high acoustic pressure buzzer. Voltage absence is indicated by high luminosity green LED.
Power supply 9V alkaline battery, type 6LR61 (included).
Indoor and outdoor use by appropiate insulating pole to the detector voltage range.
Connection to the pole by Universal head. Supplied with metallic box.
According to IEC 61243:2003+A1:2009 and UNE-EN 61243-1:2006+A1:2011 standards.
 
646 VTA-63/150-U
  • Rated voltage from: 63 to 150 kV
  • Frequency: 50 / 60 Hz
 
646 VTA-66/220-U
  • Rated voltage from: 66 to 220 kV
  • Frequency: 50 / 60 Hz
 
646 VTA-90/225-U
  • Rated voltage from: 90 to 225 kV
  • Frequency: 50 / 60 Hz
 
646 VTA-150/420-U
  • Rated voltage from: 150 to 420 kV
  • Frequency: 50 / 60 Hz
 
646 VTA-45/420-U*
  • Rated voltage from: 45 to 420 kV
  • Frequency: 50 / 60 Hz
 
646 VTA-225/420-U*
  • Rated voltage from: 225 to 420 kV
  • Frequency: 50 / 60 Hz
*Manufactured according to IEC 61243:2003+A1:2009 and UNE-EN 61243-1:2006+A1:2011 standards (except voltage range).